Design of a 500 kWp Photovoltaic System for Industrial Self-Consumption

INCIMAT developed the design for a 500 kWp industrial self-consumption photovoltaic system, aimed at reducing energy consumption from the grid and improving the economic and environmental efficiency of a production facility. The project included an analysis of the facility’s energy…

Energy Efficiency Improvement Plan for an Existing Commercial Building

INCIMAT developed an energy efficiency plan for an existing commercial building, with the goal of reducing energy consumption, optimizing the operation of the facilities, and improving user comfort through the implementation of technically feasible and cost-effective measures. The project began…

Hygrothermal Study and Condensation Prevention in a Renovated Building

INCIMAT conducted a hygrothermal study aimed at evaluating the performance of the building envelope of an existing structure undergoing an energy retrofit, analyzing the risk of surface and interstitial condensation in exterior walls, roofs, and building joints. The project included…

Justification of Energy Compliance for a Multi-Family Residential Building

INCIMAT developed the energy justification for a multi-family residential building, verifying compliance with the requirements established by current regulations regarding energy efficiency and energy demand limitation. The project included an analysis of the building’s thermal envelope—covering facades, roofs, floors, openings,…

Advanced Energy Simulation of a Corporate Office Complex

INCIMAT developed an advanced energy simulation for a corporate office complex, evaluating the building’s thermal performance and energy demand under various usage and operating conditions. The project included energy modeling of the building, taking into account its geometry, orientation, thermal…

Thermal Load Analysis for an Energy-Efficient Office Building

INCIMAT conducted a thermal load analysis for an energy-efficient office building, evaluating the heating and cooling requirements necessary to ensure indoor comfort and optimize the performance of the building systems. The work included a study of the building envelope, building…

Verification of Complex Metal Connections in an Industrial Process Tower

INCIMAT conducted a structural verification of complex steel connections in an industrial process tower, analyzing the load-bearing behavior of the main joints subjected to high stresses resulting from the facility’s operation. The work included the evaluation of connections between columns,…

Structural Analysis of Continuous Concrete Beams in an Administrative Building

INCIMAT conducted a structural analysis of reinforced concrete continuous beams integrated into an administrative building, evaluating their strength and deformation behavior within the building’s overall structural system. The work included defining the permanent and variable loads, evaluating the stresses in…